PRODUCTS DETAILS

GCS Withdrawable Switchgear

Outline

GCS withdrawable switchgear is suitable for power conversion, distribution and control in low-voltage distribution system of power, power distribution, motor control center, capacitance compensation, etc. Such as power plants, substations, petrochemical, factories and mining enterprises, hotels and high-rise buildings and other low-voltage distribution systems


Executive standard

IEC 60439-1 Low voltage switchgear and control-gear assemblies

Part 1:Type test and partial type test assemblies

GB 7251.1 Low voltage switchgear and controlgear assemblies

Part 1: type test and partial type test assemblies

JB/T 9661-1999 Low voltage withdrawable switchgear and other standards


Service Environment

● The ambient air temperature shall not exceed + 40 ℃, and the average temperature within 24h shall not exceed + 35 ℃.

● The lower limit of ambient air temperature is - 5 ℃.

● For indoor installation and use, the altitude of the place of use shall not exceed 2000m.

● The air shall be clean. When the maximum temperature is + 40 ℃, the relative humidity shall not exceed 50%; Higher relative humidity is allowed at lower temperatures. For example, the relative humidity is 90% at + 20 ℃, but considering the change of temperature, moderate condensation may occur occasionally.

● During installation, the inclination with the vertical plane shall not exceed 5 °.

● The device is suitable for the transportation and storage process of the following temperatures: - 25 ℃ - + 55 ℃, up to 70 ℃ in a short time (no more than 24h). Under these limit temperatures, the device shall not suffer any irreparable damage, and shall be able to work normally under normal conditions.

● The device shall be installed where there is no violent vibration and impact, and where the electrical components are not enough to be corroded.

● If the above service conditions cannot be met, the user shall negotiate with the company.


Specification

1. Basic Technical parameter

ITEM

Technical Data

Rated insulation voltage Ui

AC 660(1000)V

Rated working voltage Ue

Main Circuit

AC 380(660)V

Auxiliary circuit

AC 380V/220V/24V
DC 220V/110V

Rated Frequency

50-60Hz

Rated Current

Horizontal bus-bar

≤4000A

Vertical bus-bar

1000A

Rated short-time (1s)withstand current lcw

50(80) kA

Rated peak withstand current lpk

105(176)kA

Protection Level

IP 40 , upto IP54


a) Main circuit scheme of switchgear

There are 32 groups and 118 specifications in total, and the rated working current is 4000A, which is suitable for distribution transformers of 2500kVA and below.


b) Auxiliary circuit scheme of switchgear

There are 120 auxiliary circuit schemes of switchgear


c) Bus-bar

All busbars adopt TMY - T2 series hard copper bar.

i.Horizontal bus is placed in the rear of the cabinet bus compartment, 3150A and above for the upper and lower double layer layout, 2500A and below for the single layer layout.


Horizontal busbar in switchgear

Item

Rated Current(A)

Specification (mm)

1

630

50*5

2

1250

60*10

3

1600

80*10

4

2000

100*10

5

2500

2*(80*10)

6

3150

2*(100*10)

7

4000

3*(100×10)


ii. The vertical bus adopts high-quality hard copper tinned bus 40*6/60*6/100*6


Measurement

Item

(H) mm

(W) mm

(D) mm

1

2200

400

800

2

1000

600

800

3

1000

800

600

4

800

1000

1000

5

600

800

1000


image009(001)



Hot Products

Dry Type Cast Resin Transformer

Dry Type Cast Resin Transformer

Dry Type Transformer With On Load Tap Changer

Dry Type Transformer With On Load Tap Changer

Mns Electrical Board

Mns Electrical Board

Vauum Load Switch

Vauum Load Switch

Indoor Vacuum Circuit Breaker

Indoor Vacuum Circuit Breaker

Oil Filled Transformer

Oil Filled Transformer

3 Phase Isolation Transformer

3 Phase Isolation Transformer

Single Phase Isolation Transformer

Single Phase Isolation Transformer

SF6 Ring Main Unit

SF6 Ring Main Unit

Cable Distribution Cabinets

Cable Distribution Cabinets

SGB Dry Type Transformer

SGB Dry Type Transformer

Single Phase Pad Mounted Transformer

Single Phase Pad Mounted Transformer

Oil Immersed Distribution Transformer With Conservator

Oil Immersed Distribution Transformer With Conservator

KYN28 Switchgear

KYN28 Switchgear

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours